WSFU Demand & Service Pipe Sizer

Aggregate plumbing fixture schedules into Water Supply Fixture Units (WSFU) and calculate peak design flow (GPM) using Hunter's Curve per 2024 IPC Appendix E and Table 604.5.

Trades & Construction
Standard: 2024 International Plumbing Code (IPC) Table 604.5 & Appendix E

System Hydraulic Configuration

Governing codes: 2024 IPC Section 604 & Appendix E

Residential Fixture Schedule (IPC Table 604.5)

Aggregated Fixture Schedule Summary7 active fixtures

Fixture DescriptionCountUnit WSFUSubtotal
Water Closet (Tank Type)32.57.5
Lavatory Basin31.03.0
Bathtub / Shower Combo22.04.0
Kitchen Sink11.51.5
Automatic Dishwasher11.51.5
Clothes Washing Machine12.02.0
Exterior Hose Bibb(s)22.53.5
Total Demand13—23 WSFU
IPC Appendix E Peak DemandOPTIMAL
15.5 GPM

Probable peak instantaneous flow for 23 WSFU via Hunter's Curve

Min Service Pipe1"Type L Copper
AWWA Meter3/4"AWWA C700 Sizing

Velocity & Hydraulic Integrity

Fluid Velocity at Peak Flow6.03 FPS
0 FPS5 FPS (Quiet/Hot)8 FPS (IPC Max)10+ FPS
Nominal Internal Diameter:1.025 in
Code Velocity Threshold:8 FPS max
Hunter's Curve vs. Simple Fixture Addition

Plumbing systems are designed around simultaneous probability, not simple arithmetic addition. If every fixture in a 3-bath house ran simultaneously, total demand would exceed 35 GPM. Roy B. Hunter's statistical analysis proves that probability of concurrent operation peaks at only 15–20% of that maximum, preventing unnecessary utility line oversizing and excessive water aging in oversized mains.

Email LinkText/SMSWhatsApp

Calculation Provenance & Validation Record

Method

Water Supply Fixture Unit Demand via Hunter's Curve

Formula
Qpeak=HuntersCurve(∑WSFU)[GPM]Q_{peak} = \text{HuntersCurve}(\sum WSFU) \quad [\text{GPM}]
Assumptions
  • Table 604.5 fixture weights
  • Flush tank vs flushometer valve segregation
  • Maximum velocity 8.0 FPS cold / 5.0 FPS hot
References
  • International Plumbing Code (IPC) (2024 Edition) — IPC Appendix E Section E103 & Table 604.5
Last substantive review:
Automated test status: 1 golden test vectors passing (GOLDEN-TRADE-PLUMB-WSFU-01)
Method, assumptions & governing standards
Standard Sourced

Calculation Methodology

Water Supply Fixture Unit (WSFU) conversion to peak design flow rate (GPM) via Hunter curve probability models per IPC Appendix E.

Governing Standard 2024 Edition

Standard:International Plumbing Code (IPC)

Statutory building, electrical, and mechanical codes vary by jurisdiction. Confirm local municipality amendments before installation.

Key Assumptions & Constraints

  • Fixture unit weights assigned according to IPC Table 604.5
  • Separate curves evaluated for flush tank vs. flushometer valve distribution branches
  • Maximum water velocity limited to 8.0 FPS for cold water and 5.0 FPS for hot water to prevent pipe erosion
Regression Tests: 3 golden vectors
Last Verified:
Primary References: 2 documented
Field Trade Notice: For trade planning and engineering estimates. Final installations must conform to project blueprints, authority having jurisdiction (AHJ) code approvals, and site-specific inspections.